Service difficulty report · Apu · Bombdr BD1001A10

Difficulty date
May 30, 2019
Submitted
August 17, 2020
Operation
General aviation
Make and model
Bombdr BD1001A10
Part
Apu
Part number
3800775
Condition
Malfunctioned
Stage of operation
NR
How discovered
O
Nature of condition
N
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

(CAN) PER THE CREW DURING THE CRUISE PHASE AT 11,000FT CREW RECEIVED A APU FIRE INDICATION MESSAGE. CREW THEN CONSULTED THE QRH, DEPLOYED THE FIRE BOTTLE, DECLARED EMERGENCY AND LANDED WITHOUT FURTHER INCIDENT. UPON LANDING FIRE DEPARTMENT MET CREW AT A/C AND CONFIRMED NO FIRE DAMAGE. CUSTOMER MAINTENANCE IS SUPPORTING AND FOUND APU FIRE WALL & APU MOUNTS WERE NOT SEALED - FIRE BOTTLE REPLACED AND SEALANT APPLIED TO APU FIREWALL (TC# 20191216013)