Service difficulty report · Circuit Breaker · Boeing 737275

Difficulty date
October 21, 1995
Submitted
March 26, 2000
Operation
Air carrier
Make and model
Boeing 737275
Part
Circuit Breaker
Condition
Malfunction
Location
Nr 2 Eng Ai
Stage of operation
CL
Nature of condition
O
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

(CAN)CIRCUIT BREAKER #2 ENGINE AND WING ANTI-ICE POPPED AFTER USING ENGINE ANTI-ICE. ON ARRIVAL CIRCUIT BREAKER RESET AND VALVE OPERATION CHECKED NORMAL. CONNECTORS REMOVED FROM THREE VALVES AND INSPECTED.NO EVIDENCE OF ARCING. CIRCUIT BREAKER REPLACED ON SPEC.