Service difficulty report · Press.Controller · Doug DC932

Difficulty date
February 22, 1996
Submitted
March 26, 2000
Operation
Air carrier
Make and model
Doug DC932
Engine
Pwa JT8D7A
Part
Press.Controller
Part number
21011404
Condition
Failed
Location
Nr 1 & Nr 2
Stage of operation
CL
Nature of condition
J
Precautionary procedure
B

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

(CAN)AFTER TRAKEOFF AT FL.290, MASTER CAUTION LIGHT ILLUMINATED INDICATING A PRESSURIZATION PROBLEM. QRH DRILL CARRIED OUT, INITIATED EMERGENCY DESCENT AND MANUALLY DEPLOYED OXYGEN MASKS. ON RETURN MAINTEN ANCE ACTION INVOLVED CHANGING #1 AND #2 PRESSURIZATION CONTROLLERS.

More about the Doug DC-9-32