Service difficulty report · Prox.Sensor · Airbus A320211

Difficulty date
March 24, 1996
Submitted
March 26, 2000
Operation
Air carrier
Make and model
Airbus A320211
Part
Prox.Sensor
Condition
Out Of Rig
Location
Flap
Stage of operation
AP
Nature of condition
F
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

(CAN)ON APPROACH WHEN FLAP 2 SELECTED ECAM MESSAGE "F/CTL FLAPS LOCKED ALIGNMENT FAULT". ECAM ACTIONS COMPLETED, LANDING NORMAL. MAINTENANCE FOUND RIGHT FLAP INTERCONNECTING STRUT WITH BOTH SENSORS OUT OF RIG. BOTH PROXIMITY SENSORS RIGGED AS PER M.M. 27-51-44 AND INSPECTION CARRIED OUT ON BOTH FLAPS INTERCONNECTING STRUT. OPERATIONAL CHECK CARRIED OUT.