As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
(CAN)ON APPROACH WHEN FLAP 2 SELECTED ECAM MESSAGE "F/CTL FLAPS LOCKED ALIGNMENT FAULT". ECAM ACTIONS COMPLETED, LANDING NORMAL. MAINTENANCE FOUND RIGHT FLAP INTERCONNECTING STRUT WITH BOTH SENSORS OUT OF RIG. BOTH PROXIMITY SENSORS RIGGED AS PER M.M. 27-51-44 AND INSPECTION CARRIED OUT ON BOTH FLAPS INTERCONNECTING STRUT. OPERATIONAL CHECK CARRIED OUT.