Service difficulty report · Eye Bolt · Dhav DHC3

Difficulty date
May 30, 1996
Submitted
March 26, 2000
Operation
Air carrier
Make and model
Dhav DHC3
Part
Eye Bolt
Part number
WAL96
Condition
Elongated
Location
Floats
Part time
10,000 hours
Component
Edo · 557170A
Stage of operation
IN
Nature of condition
O
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

(CAN) DURING ANNUAL INSPECTION OF FLOAT INSTALLATION, 2 OF 8 EYE BOLTS ATTACHING SPREADER BARS WERE FOUND BADLY ELONGATED. SUSPECT CAUSE - CONSIDERED POOR MAINTENANCE AS SOME AME'S ARE TRYING TO REMOVE FLOAT ASSEMBLIES TIED TOGETHER WITH THE SPREADER BARS. THEY NEED TO BE REMOVE INDIVIDUALLY. EYE BOLTS, BRACKETS AND SPREADERS ARE NOT DESIGNED TO HOLD FLOATS TOGETHER WHEN OFF AIRCRAFT. EXTREME BENDING AND SHEAR LOADS ARE APPLIED TO THOSE PARTS WHEN REMOVAL AND INSTALLATION OF THE FLOATS IS NOT CARRIED OUT PROPERLY.