Service difficulty report · Sensor · Airbus A320211

Difficulty date
June 19, 1996
Submitted
March 26, 2000
Operation
Air carrier
Make and model
Airbus A320211
Part
Sensor
Condition
Failed
Location
Flap 40cv
Stage of operation
AP
Nature of condition
F
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

(CAN) DURING APPROACH WHEN FLAP 2 SELECTED FLAP LOCKOUT OCCURRED. PERFORMED QUICK REFERENCE HANDBOOK (QRH) LANDING. REQUIRED MAINTENANCE ACTION (R.M.A.) 27-50-867 COMPLETED. INTERCONNECT SENSOR 40 CV REPLACED. FLAP OPERATION CARRIED OUT.