Service difficulty report · Cable · Stbros SD360

Difficulty date
July 16, 1996
Submitted
March 26, 2000
Operation
Air carrier
Make and model
Stbros SD360
Engine
Pwa PT6A65AR
System (JASC)
7603 · Power Lever
Part
Cable
Part number
SD3476160
Condition
Frayed
Location
Sta 75.45
Stage of operation
LD
Nature of condition
O
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

(CAN) CABLE FRAYED AT PULLEY LOCATION STA 75.45 FOR LEFT ENGINE POWER CONTROL. CABLE WAS LAST INSPECTED PER SD360-76-08R1, 414 HOURS PREVIOUSLY. COULD NOT ACHIEVE REVERSE THRUST. IN ADDITION A CHANGE WAS NOTED IN N1 SPEEDS AT WHICH AUTOFEATHER AND RTOP ARMING LIGHTS CAME ON DUE TO OUT OF RIG POWER LEVERS.