As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
(CAN) STARTER FIELD COILS LOOSE ON POLE SHOES RUBBED ON THE THROUGH BOLTS CREATING A DEAD HIGH AMPERAGE SHORT RESULTING IN BOTH MASTER SOLENOID AND STARTER SOLENOID CONTACT PLATES WELDING TO TERMINALS - A VERY DANGEROUS AND FIRE CONDITION - SUSPECT INSUFFICIENT CLEARANCE IN DESIGN AND/OR MANUFACTURE BETWEEN COIL AND THROUGH BOLTS.