Service difficulty report · Flap Actuator · Diamon DA20A1

Difficulty date
November 6, 1996
Submitted
March 26, 2000
Operation
Air carrier
Make and model
Diamon DA20A1
Part
Flap Actuator
Part number
2027500500
Condition
Out Of Position
Location
Plastic Collar
Part time
633 hours
Stage of operation
IN
Nature of condition
O
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

(CAN) PLASTIC COLLAR FOUND OUT OF POSITION IN THE FLAP ASSMEBLY. SUBMITTER BELIEVES IT VIBRATED OUT OF ITS SECURE LOCATION AND WAS MOVING ALONG THE SHAFT. SUBMITTER IS CONCERNED THAT IT COULD POSSIBLY JAM THE FLAP.