Service difficulty report · Hyd Pump · Airbus A310324

Difficulty date
January 24, 1997
Submitted
March 26, 2000
Operation
General aviation
Make and model
Airbus A310324
Engine
Pwa PW4152
Part
Hyd Pump
Part number
6506606
Condition
Sheared Spline
Location
#1 System
Stage of operation
CR
Nature of condition
K
Precautionary procedure
H

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

(CAN) GREEN HYDRAULIC SYSTEM DEPLETED IN FLIGHT. GROUND INSPECTION FOUND THE #1 GREEN SYSTEM ENGINE DRIVEN PUMP (EDP) DRIVE SHAFT HAD SHEARED INTERNALLY. PUMP CASE LEAKED, CAUSING LOSS OF GREEN SYSTEM HYDRAULIC FLUID.