Service difficulty report · Elect Receptacle · Doug DC932

Difficulty date
March 1, 1997
Submitted
March 26, 2000
Operation
Air carrier
Make and model
Doug DC932
Engine
Pwa JT8D7A
Part
Elect Receptacle
Condition
Electrical Shock
Location
Posit Nr 17
Stage of operation
CR
Nature of condition
O
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

(CAN) FLIGHT ATTENDANT RECEIVED ELECTRICAL SHOCK WHEN PULLING FOOD CART OUT FROM POSITION #17. ELECTRICAL POWER AND GROUND CHECKED AT RECEPTACLE. NO FAULT FOUND. RECEPTACLE REMOVED FROM BRACKET, WIRING AND GROUND STRAP CHECKED AND FOUND SERVICEABLE. RECEPTACLE REACTIVATED.