What was found
(CAN) DURING HSI GBI, THE COMPRESSOR SECTION WAS DISMANTLED DUE TO COMPRESSOR RUB. 1ST STAGE IMPELLER HAS A CRACK IN IT. THIS PN IS REFERENCED IN SB TPE331A72-0971. REPLACED. PART TC: 11,482 HOURS.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
(CAN) DURING HSI GBI, THE COMPRESSOR SECTION WAS DISMANTLED DUE TO COMPRESSOR RUB. 1ST STAGE IMPELLER HAS A CRACK IN IT. THIS PN IS REFERENCED IN SB TPE331A72-0971. REPLACED. PART TC: 11,482 HOURS.