What was found
(CAN) A FAIR AMOUNT OF WEAR BEYOND LIMITS WAS FOUND ON THE END OF THE FERRULES OF THE SECONDARY FLAP DRIVES IT APPEARS THAT THE BEARINGS IN THE COUPLINGS ARE SPINNING AGAINST THE FERRULES AND CAUSING THE WEAR. IT WAS NOTED THAT SEVERAL OTHER SECTIONS OF THE SECONDARY DRIVE OUTER CASINGS HAVE THE SAME WEAR ON THE FERRULE END. THE WEAR LIMITS ARE ONLY .005. THE SUBMITTER EXPECTS TO SEE A LOT OF THESE IN THE FUTURE.