Service difficulty report · Element · Cvac 340CVAC

Difficulty date
October 14, 1997
Submitted
March 26, 2000
Operation
Air carrier
Make and model
Cvac 340CVAC
Engine
Allsn 501D13
Part
Element
Part number
355900575
Condition
High Resistance
Location
Zone 2 Nr1 Eng
Part time
1,258 hours
Component
355900
Stage of operation
CR
Nature of condition
J, N
Precautionary procedure
E, F

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

(CAN) DURING FLIGHT FIRE WARNING FOR NR1 ENGINE ZONE 2 CAME ON. PRECAUTIONARY SHUT DOWN OF NR1 ENGINE CARRIED OUT AND BOTH LEFT HAND FIRE BOTTLES DISCHARGED. SUBSEQUENT MAINTENANCE ACTION FOUND FIRE SENSE ELEMENT AT FAULT. ELEMENT AND DISCHARGED FIRE BOTTLES REPLACED.