Service difficulty report · Circuit Breaker · Dhav DHC6100

Difficulty date
December 12, 1997
Submitted
March 26, 2000
Operation
Air carrier
Make and model
Dhav DHC6100
Engine
Pwa PT6A20
Part
Circuit Breaker
Part number
D727185
Condition
Fused
Location
Cockpit Overhead
Stage of operation
IN
Nature of condition
B
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

(CAN) WHEN GROUND POWER APPLIED, AND CABIN LIGHTS SELECTED ON, SMOKE WAS OBSERVED COMING FROM THE OVERHEAD CIRCUIT BREAKER PANEL. WIRING FOR THE LEFT HAND CABIN LIGHTS DIM WAS FOUND COMPLETELY BURNT. THE 5 AMP CIRCUIT BREAKER WAS FUSED IN THE CLOSED POSITION. THE CB COULD NOT TRIP AND THE FIRST DIM LIGHT SOCKET WAS SHORTED CAUSING THE PROBLEM. SEVERAL SOCKETS WERE REPLACED BECAUSE OF CORROSION AND BAD CONNECTIONS. SUBMITTER SUSPECTS THAT THE CB PROBLEM MAY HAVE BEEN CAUSED BY REPEATED RESETTING OF IT IN-FLIGHT.