Service difficulty report · Pump · Dhav DHC8102

Difficulty date
April 9, 1998
Submitted
March 26, 2000
Operation
General aviation
Make and model
Dhav DHC8102
Part
Pump
Part number
570347
Condition
Failed
Location
Nr 2
Component
Vickers
Stage of operation
CL
Nature of condition
J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

(CAN) AFTER TAKEOFF THROUGH 140 KNOTS, THE NR 2 HYDRAULIC PRESSURE CAUTION LIGHT, THE RUDDER PRESSURE, AND RUDDER FULL PRESSURE CAUTION LIGHTS CAME ON. ON APPROACH, THE CAUTION LIGHTS WENT OUT. INVESTIGATION FOUND THE ENGINE DRIVEN PUMP HAD A SPLIT FLANGE.