Service difficulty report · Wire · Beech 1900D

Difficulty date
April 9, 1998
Submitted
March 26, 2000
Operation
General aviation
Make and model
Beech 1900D
Engine
Pwa PT6A67D
Part
Wire
Part number
A24P170J
Condition
Misrouted
Location
Dc System
Part time
4,308 hours
Component
Raythn · 1293800161
Stage of operation
IN
How discovered
O
Nature of condition
W
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

(CAN) IN REFERENCE TO ELECTRICAL LOAD DISTRIBUTION, DC POWER RIGHT WIRING DIAGRAM MANUAL ATA 24-61-02, WIRE NR A2-4-P170-J WAS CONNECTED TO TERMINAL NR 5 INSTEAD OF TERMINAL NR 4. IN THIS SITUATION, THE RIGHT GENERATOR WAS HARD TO COME ON LINE AFTER ENGINE START. THIS OCCURRED ONLY AFTER BATTERY START WITHOUT GROUND POWER.

More about the Beech 1900D