What was found
(CAN) IN REFERENCE TO ELECTRICAL LOAD DISTRIBUTION, DC POWER RIGHT WIRING DIAGRAM MANUAL ATA 24-61-02, WIRE NR A2-4P170-J WAS CONNECTED TO TERMINAL NR 5 INSTEAD OF TERMINAL NR 4. IN THIS SITUATION, THE RIGHT GENERATOR WAS HARD TO COME ON LINE AFTER AN ENGINE START. THIS OCCURRED ONLY AFTER A BATTERY START WITHOUT GROUND POWER.