Service difficulty report · Fire Loop · Cvac 340CVAC

Difficulty date
August 19, 1998
Submitted
March 26, 2000
Operation
Air carrier
Make and model
Cvac 340CVAC
Engine
Allsn 501D13D
Part
Fire Loop
Part number
355900575
Condition
Malfunctioned
Location
Nr 2 Engine
Stage of operation
CR
Nature of condition
N
Precautionary procedure
E, F

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

(CAN) DURING CRUISE, INTERMITTENT ZONE 2 WARNING LIGHT AND BELL (NR 2 ENG). LIGHT CONTROLLED BY REDUCING POWER. HOWEVER, ON DESCENT, LIGHT AND BELL ILLUMINATED STEADY. ENGINE SHUTDOWN AND FIRE BOTTLES FIRED. BOTTLES AND SQUIBS REPLACED. RT ENG ZONE 2 FIRE LOOP REPLACED.