Service difficulty report · Ground Strap · Cndair CL6002B19

Difficulty date
November 1, 1998
Submitted
March 26, 2000
Operation
General aviation
Make and model
Cndair CL6002B19
Part
Ground Strap
Condition
Shorted
Location
Piccolo Tube
Stage of operation
CR
Nature of condition
J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

(CAN) DURING FLIGHT, THE 'WING ANTI-ICE DUCT RT' APPEARED ON SEVERAL OCCASIONS. INVESTIGATION FOUND THE GROUNDING STRAP OF THE PICCOLO TUBE WAS TOUCHING THE HEAT SENSOR. WIRE REPOSITIONED.