What was found
(CAN) AFTER PERFORMING MAINTENANCE ON THE FLAP SYSTEM, WHILE RETRACTING THE FLAPS, THE FLAP DRIVE CAUTION LIGHT ILLUMINATED. INVESTIGATION REVEALED THE ELASTOMERIC COUPLINGS AT BOTH ENDS OF THE RIGHT INBOARD TORQUE TUBE HAD FAILED.