What was found
(CAN) REPORT OF ELEVATOR FEEL NOT NORMAL. THIS SNAG GENERATED AFTER FIRST FLIGHT AFTER HEAVY MAINTENANCE VISIT. ELEVATOR FEEL BREAKOUT TORQUE WITHIN LIMITS. WAS PREVIOUS SAME SNAG. ELEVATOR COMPUTER REPLACED AND ELEVATOR CABLES CHECKED FOR PROPER TENSION. HINGE BEARINGS GREASED. LIGHT TEST ACCOMPLISHED, PILOT REPORTED ELEVATORS WERE NORMAL. NEXT FLIGHT CREW REPORTED HEAVY ELEVAROT, WITH A DEAD BAND IN CENTER OF TRAVEL. TROUBLESHOOTING FOUND BINDING WHEN CONTROL COLUMN OPERATING FORE AND AFT. CONTROL COLUMN DUST SHIELDS ADJUSTED TOO TIGHT. FOD FOUND, SPLIT PIN TRAPPED UNDER F/OS DUST SHIELD. CONTROL COLUMN DUST SHIELDS ADJUSTED PER MM. SERVICEABLE.