What was found
31J - INSPECTION FOUND A 1 INCH CRACK IN THE LEFT LEADING EDGE NR 3 SLAT NR 1 HINGE DOOR AREA. THE CRACK WAS STOP DRILLED AND A REPAIR WAS INSTALLED IAW SRM 51-10-2, 57-30-4, AND 51-30-2. (X)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
31J - INSPECTION FOUND A 1 INCH CRACK IN THE LEFT LEADING EDGE NR 3 SLAT NR 1 HINGE DOOR AREA. THE CRACK WAS STOP DRILLED AND A REPAIR WAS INSTALLED IAW SRM 51-10-2, 57-30-4, AND 51-30-2. (X)