What was found
GSO - INSPECTION FOUND AFT GIRT BAR ATTACH FITTING BRACKET AND FLOOR BEAM CORRODED AT FS 344. THE CORROSION WAS REMOVED AND REPAIR PARTS WERE FABRICATED IAW SRM 51-40-2 AND ECRA 5310C01102. A REPAIR WAS INSTALLED IAW SRM 51-30-2. (X)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
GSO - INSPECTION FOUND AFT GIRT BAR ATTACH FITTING BRACKET AND FLOOR BEAM CORRODED AT FS 344. THE CORROSION WAS REMOVED AND REPAIR PARTS WERE FABRICATED IAW SRM 51-40-2 AND ECRA 5310C01102. A REPAIR WAS INSTALLED IAW SRM 51-30-2. (X)