What was found
DHN - INSPECTION FOUND INTERGRANULAR CORROSION ON FLOORBEAM TOP CAP AT STA 328, LBL 20 TO RBL 40. THE FLOORBEAM CAP WAS REPLACED FROM LBL 65 TO RBL 65 IAW SRM 51-40-4. (W)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.