What was found
GSO - INSPECTION FOUND A .5 INCH CRACK IN FLOOR SUPPORT FLANGE AT BS 990. A NEW FLOOR SUPPORT ANGLE WAS FABRICATED AND INSTALLED IAW SRM 51-40-4 AND 53-10-2. (W)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
GSO - INSPECTION FOUND A .5 INCH CRACK IN FLOOR SUPPORT FLANGE AT BS 990. A NEW FLOOR SUPPORT ANGLE WAS FABRICATED AND INSTALLED IAW SRM 51-40-4 AND 53-10-2. (W)