What was found
KUL - INSPECTION FOUND CORROSION ON FRAME CAPS AT STATION 1701 AND 1721 BETWEEN LONGERONS 50L AND 50R. THE FRAME CAPS WERE REPAIRED IAW ECRA 5310-03101. (W)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
KUL - INSPECTION FOUND CORROSION ON FRAME CAPS AT STATION 1701 AND 1721 BETWEEN LONGERONS 50L AND 50R. THE FRAME CAPS WERE REPAIRED IAW ECRA 5310-03101. (W)