What was found
GSO - INSPECTION FOUND CORROSION ON FRAME ABOVE STRINGER 26R AT STATION 529. A NEW FRAME AND SPLICE WERE FABRICATED AND INSTALLED IAW SRM 53-10-3 AND 51-30-2. (W)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
GSO - INSPECTION FOUND CORROSION ON FRAME ABOVE STRINGER 26R AT STATION 529. A NEW FRAME AND SPLICE WERE FABRICATED AND INSTALLED IAW SRM 53-10-3 AND 51-30-2. (W)