What was found
GSO - INSPECTION FOUND A .5 INCH CRACK IN WEB LOWER ATTACH ANGLE OF RT WING LEADING EDGE CAVITY AT STATION 119. A REPAIR ANGLE WAS FABRICATED AND INSTALLED IAW SRM 51-40-3 AND 51-30-2. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
GSO - INSPECTION FOUND A .5 INCH CRACK IN WEB LOWER ATTACH ANGLE OF RT WING LEADING EDGE CAVITY AT STATION 119. A REPAIR ANGLE WAS FABRICATED AND INSTALLED IAW SRM 51-40-3 AND 51-30-2. (M)