SDR CAL950534

Service difficulty report · Fuel Control · Doug DC982

Difficulty date
July 3, 1995
Submitted
March 26, 2000
Operation
Air carrier
Aircraft
N819NY
Make and model
Doug DC982
Aircraft serial
49479
Part
Fuel Control
Part number
360800010
Condition
Inoperative
Location
Apu
Part time
13,735 hours
Stage of operation
CR
Nature of condition
J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

SLC - FLT 0288 - WHILE OPERATING THE APU AT CRUISE WITH THE LEFT GENERATOR SYSTEM PLACARDED INOPERATIVE, THE APU RPM SLOWLY INCREASED THROUGH 104 PERCENT TO 105 PERCENT AND THEN SHUT DOWN. THE AIRCRAFT WAS DIVERTED TO SLC WHERE IT LANDED WITHOUT INCIDENT. MAINTENANCE RAN THE APU AND ALL PARAMETERS WERE WITHIN LIMITS. THE APU WAS RESTARTED SEVERAL TIMES AND RAN AT 103 PERCENT DURING ALL RUNS. THE APU CONTINUED TO HAVE PROBLEMS ON A SUBSEQUENT FERRY FLIGHT. THE APU FUEL CONTROL UNIT WAS REMOVED AND REPLACED AND OPERATION OF THE APU CHECKED NORMAL. (X)

More about the Doug DC-9-82