What was found
GSO - INSPECTION FOUND CORROSION ON INTERCOSTAL FLANGE AT STATION 847-867 BELOW STRINGER 24. A NEW INTERCOSTAL WAS FABRICATED AND INSTALLED IAW SRM 53-10-2 AND 51-30-2. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
GSO - INSPECTION FOUND CORROSION ON INTERCOSTAL FLANGE AT STATION 847-867 BELOW STRINGER 24. A NEW INTERCOSTAL WAS FABRICATED AND INSTALLED IAW SRM 53-10-2 AND 51-30-2. (M)