GSO - INSPECTION FOUND A .5 INCH CRACK IN SHEAR TIE AT VERTICAL STABILIZER STATION 25, STRINGER 7R. THE SHEAR TIE WAS REMOVED. A NEW SHEAR TIE WAS FABRICATED AND INSTALLED IAW SRM 51-30-2 AND BAC DRAWING 65-16811. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
GSO - INSPECTION FOUND A .5 INCH CRACK IN SHEAR TIE AT VERTICAL STABILIZER STATION 25, STRINGER 7R. THE SHEAR TIE WAS REMOVED. A NEW SHEAR TIE WAS FABRICATED AND INSTALLED IAW SRM 51-30-2 AND BAC DRAWING 65-16811. (M)