What was found
GSO - INSPECTION FOUND A .5 INCH CRACK IN FRAME AT STATION 420L BETWEEN STRINGERS 20L-21L. THE DAMAGE WAS CUT OUT AND A NEW FRAME, CHORD, AND SPLICES WERE INSTALLED IAW SRM 51-30-2 AND BOEING DRAWING 65C25113. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
GSO - INSPECTION FOUND A .5 INCH CRACK IN FRAME AT STATION 420L BETWEEN STRINGERS 20L-21L. THE DAMAGE WAS CUT OUT AND A NEW FRAME, CHORD, AND SPLICES WERE INSTALLED IAW SRM 51-30-2 AND BOEING DRAWING 65C25113. (M)