DHN - INSPECTION FOUND CORROSION AT NUT PLATES ON FLOOR SUPPORT INBOARD OF STRINGER 26L IN AFT CARGO COMPARTMENT AT BS 727E-793. THE CORROSION WAS REMOVED AND A REPAIR WAS INSTALLED IAW SRM 51-10-01 AND 51-30-02. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DHN - INSPECTION FOUND CORROSION AT NUT PLATES ON FLOOR SUPPORT INBOARD OF STRINGER 26L IN AFT CARGO COMPARTMENT AT BS 727E-793. THE CORROSION WAS REMOVED AND A REPAIR WAS INSTALLED IAW SRM 51-10-01 AND 51-30-02. (M)