What was found
DHN - INSPECTION FOUND CORROSION ON ANGLE IN AFT CARGO BILGE AREA AT STATION 794, ABOVE STRINGER 26R. A NEW ANGLE WAS FABRICATED AND INSTALLED IAW SRM 51-10-1. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DHN - INSPECTION FOUND CORROSION ON ANGLE IN AFT CARGO BILGE AREA AT STATION 794, ABOVE STRINGER 26R. A NEW ANGLE WAS FABRICATED AND INSTALLED IAW SRM 51-10-1. (M)