What was found
IAH - INSPECTION FOUND TWO 'Z' CHANNELS CRACKED AT TOP OF CANNON PLUG COMPARTMENT OF NR 1 ENGINE PYLON. THERE WERE THREE CRACKS MEASURING 4.125 INCHES, 1.5 INCHES AND 1.25 INCHES LONG. TWO NEW 'A' CHANNELS WERE FABRICATED AND INSTALLED IAW SRM 54-10-0, PAGE 2, FIGURE 1. (M)