What was found
HOU - INSPECTION FOUND A 3 INCH CRACK EXTENDING FROM FASTENER IN FRAME AT STATION 794, STRINGER 18L. THE FRAME WAS REPAIRED IAW SRM 53-11-3, FIGURE 1. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
HOU - INSPECTION FOUND A 3 INCH CRACK EXTENDING FROM FASTENER IN FRAME AT STATION 794, STRINGER 18L. THE FRAME WAS REPAIRED IAW SRM 53-11-3, FIGURE 1. (M)