What was found
INSPECTION FOUND A 1.5 INCH CRACK IN FRAME AROUND RADIUS TO TOOL HOLE AT BS 970 BETWEEN S26L AND S27L. THE CRACK WAS STOP DRILLED AND A DOUBLER WAS INSTALLED IAW SRM 53-30-3 AND 51-40-2. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION FOUND A 1.5 INCH CRACK IN FRAME AROUND RADIUS TO TOOL HOLE AT BS 970 BETWEEN S26L AND S27L. THE CRACK WAS STOP DRILLED AND A DOUBLER WAS INSTALLED IAW SRM 53-30-3 AND 51-40-2. (M)