What was found
INSPECTION FOUND A .5 INCH CRACK IN LATERAL FLOOR BEAM WEB AT CABLE PASS THROUGH, BS 840, LBL 54. THE CRACK WAS STOP DRILLED. A WEB REPAIR WAS FABRICATED AND INSTALLED IAW SRM 51-40-2. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION FOUND A .5 INCH CRACK IN LATERAL FLOOR BEAM WEB AT CABLE PASS THROUGH, BS 840, LBL 54. THE CRACK WAS STOP DRILLED. A WEB REPAIR WAS FABRICATED AND INSTALLED IAW SRM 51-40-2. (M)