As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
CORROSION WAS FOUND AT STATION 1130 FRAME DURING INSPECTION ON RIGHT FUSELAGE WALL. THE CORROSION EXTENDED ABOVE AND BELOW FLOOR LEVEL. THE CORRODED SECTION WAS REMOVED. A REPAIR WAS FABRICATED AND INSTALLED IAW SRM 51-10-6, 51-10-2, AND 53-10-4. (M)