What was found
HOU - INSPECTION FOUND A 1 INCH CRACK IN RIGHT SIDE FLOOR BEAM WEB AT STA 617. THE END OF WEB WAS CUT OFF AND A NEW WEB WAS SPLICED IAW SRM 53-01, FIGURE 4. (X)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
HOU - INSPECTION FOUND A 1 INCH CRACK IN RIGHT SIDE FLOOR BEAM WEB AT STA 617. THE END OF WEB WAS CUT OFF AND A NEW WEB WAS SPLICED IAW SRM 53-01, FIGURE 4. (X)