What was found
INSPECTION FOUND A 3 INCH CRACK IN STRINGER 26L IN FORWARD CARGO PIT AT STATION 620. THE CORROSION WAS REMOVED AND THE CRACK WAS STOP DRILLED. REPAIRS WERE DONE IAW SRM 51-40-1, 51-10-6, AND 51-10-3. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION FOUND A 3 INCH CRACK IN STRINGER 26L IN FORWARD CARGO PIT AT STATION 620. THE CORROSION WAS REMOVED AND THE CRACK WAS STOP DRILLED. REPAIRS WERE DONE IAW SRM 51-40-1, 51-10-6, AND 51-10-3. (M)