What was found
INSPECTION FOUND A .25 INCH CRACK IN FORWARD CARGO FRAME AT STA 600 AND CENTER FLOOR STRUCTURE. THE CRACKED SECTION OF FRAME WAS CUT OUT IAW SRM 51-40-3. A REPAIR ANGLE WAS FABRICATED AND INSTALLED IAW SRM 51-10-2 AND SRM 51-30-2. (X)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION FOUND A .25 INCH CRACK IN FORWARD CARGO FRAME AT STA 600 AND CENTER FLOOR STRUCTURE. THE CRACKED SECTION OF FRAME WAS CUT OUT IAW SRM 51-40-3. A REPAIR ANGLE WAS FABRICATED AND INSTALLED IAW SRM 51-10-2 AND SRM 51-30-2. (X)