What was found
MIA - INSPECTION FOUND CORROSION ON WEB AND FLOOR SUPPORT STRUCTURE UNDER BRACKET AT AFT SERVICE DOOR AREA, FS 1142. THE CORRODED AREAS WERE REMOVED AND REPAIRS WERE INSTALLED IAW SRM 53-01, FIGURE 2, SHEET 3 AND 4. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MIA - INSPECTION FOUND CORROSION ON WEB AND FLOOR SUPPORT STRUCTURE UNDER BRACKET AT AFT SERVICE DOOR AREA, FS 1142. THE CORRODED AREAS WERE REMOVED AND REPAIRS WERE INSTALLED IAW SRM 53-01, FIGURE 2, SHEET 3 AND 4. (M)