As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
STATION 31J - INSPECTION FOUND FLOOR SUPPORT FITTING AT BS 420 TO 440, RBL 10 AND AT BS 440 TO 460, RBL 10 CORRODED. THE FLOOR SUPPORT FITTINGS WERE REMOVED. NEW FLOOR SUPPORT FITTINGS AND FILLER WERE FABRICATED AND INSTALLED IAW SRM 51-20-2 AND 51-30-2. (M)