What was found
STATION 31J - INSPECTION FOUND FLOOR SUPPORT CORRODED AT BS 1070-1090, RBL 10. THE FLOOR SUPPORT WAS REMOVED. A REPAIR WAS FABRICATED AND INSTALLED IAW SRM 51-40-4 AND MM 51-10-2. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
STATION 31J - INSPECTION FOUND FLOOR SUPPORT CORRODED AT BS 1070-1090, RBL 10. THE FLOOR SUPPORT WAS REMOVED. A REPAIR WAS FABRICATED AND INSTALLED IAW SRM 51-40-4 AND MM 51-10-2. (M)