What was found
STATION 31J - INSPECTION FOUND G2 GALLEY FLOOR AND MOUNT BRACKET CORRODED. THE MOUNT BRACKET AND FLOOR SKIN WERE REMOVED. A NEW FLOOR SKIN WAS FABRICATED AND INSTALLED. THE CORROSION WAS CLEANED FROM BLOCK TIE DOWN AND REBONDED AND A NEW UPPER SHELF WAS INSTALLED IAW MM 25-32-0 AND SRM 51-40-9 AND 51-10-2. (M)