What was found
STATION 31J - INSPECTION FOUND BS 1263 TORQUE BOX FRAME AT VENTRAL STAIR AREA HAD A 2 INCH CRACK IN RADIUS OF REPAIR DOUBLER AFT FLANGE AND A 4 INCH CRACK BEYOND CONTAINMENT OF ONE DOUBLER AND STOP DRILL ON FORWARD FLANGE. REPAIRS WERE PERFORMED IAW CAL WORK CARD NR MFG JA5310-0246004001. FASTENERS WERE INSTALLED IAW SRM 51-30-2. PARTS CHANNEL AND FRAME SUPPORT WERE INSTALLED IAW SRM 51-10-4. (M)