SDR CAL960158

Service difficulty report · Valve · Doug DC1030

Difficulty date
February 18, 1996
Submitted
March 26, 2000
Operation
Air carrier
Aircraft
N14062
Make and model
Doug DC1030
Aircraft serial
47863
Part
Valve
Part number
AJG70415533
Condition
Leaking
Location
Horiz Stab
Part time
16,060 hours
Stage of operation
CR
Nature of condition
K, J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

FLT NR 10 - EWR - THE NR 1 HYDRAULIC SYSTEM BEGAN TO LOSE FLUID WHILE EN ROUTE FROM IAH TO ORY. THE QUANTITY DROPPED STEADILY. THE AIRCRAFT WAS DIVERTED TO EWR WHERE IT LANDED WITHOUT INCIDENT. MAINTENANCE FOUND THE LOWER PRIMARY TRIM CONTROL VALVE LEAKING. THE LOWER PRIMARY TRIM CONTROL VALVE WAS REMOVED AND REPLACED IAW MM 27-43-03, PAGE 501. LEAK AND OPERATIONAL CHECKS WERE GOOD. (M)