What was found
STATION 31J - INSPECTION FOUND A 1 INCH CRACK IN FLOOR SUPPORT ANGLE AT BS 950B, RBL 48. A NEW Z-ANGLE AND TWO PLATES WERE FABRICATED AND INSTALLED IAW SRM 51-10-2, 51-40-4, AND MM 51-20-15. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
STATION 31J - INSPECTION FOUND A 1 INCH CRACK IN FLOOR SUPPORT ANGLE AT BS 950B, RBL 48. A NEW Z-ANGLE AND TWO PLATES WERE FABRICATED AND INSTALLED IAW SRM 51-10-2, 51-40-4, AND MM 51-20-15. (M)